11-Building Structure Design
CHAPTER 11-BUILDING STRUCTURE DESIGN AND CONSTRUCTION REQUIREMENTS
11-1. Loads and Design
Structure analysis, design, detailing and loading shall be in
accordance with the requirements of current Uniform Building Code
(UBC) and American Code or British relevant Code or any other
Code. Structure shall however be designed by only one approved
Code.
11-2. Seismic Design
Seismic Risk Zone for Karachi will be zone~2B (with reference
to UBC-97) which is equivalent to Peak Ground Acceleration (PGA)
of 16% g to 24% g.
11-3. Sub Soil Investigation
In view of the structural design in Seismic hazard zone, type
of Sub-Soil for foundation should be thoroughly ascertained by
geo-technical investigation under the direct supervision of qualified
and experienced geo-technical engineers The Soil Report should
correlate the sub-soil type with UBC- 97 (or current) Sub-Soil
list.
11-4. Wind Load
Wind load should be based on the velocity and gust factors data
from local Meteorological Department.
11-5. Erection on Reclaimed site
11-5.1. No building foundation shall be erected upon a site reclaimed
by Town sweepings or other refuse, except on recommendation of
Geo-technical and Structural Engineer.
11-5.2. No building plans shall be approved on open nallahs public
sewers and the like.
11-6. Protection of Existing Services
During the making of an excavation in connection with a building
works or services, adequate precautions shall be taken to Secure
the existing services.
11-7. Foundation Near drains
Where a building is to be erected adjacent to existing buildings,
or near a drain/nallah, or an excavation at a distance less than
depth of the said drain / nallah or excavation, or such as to
affect the stability of drains / nallah, the owner, through a
Structural Engineer, shall satisfy
THE SINDH GOVT. GAZETTE APRIL 04, 2002 477
11-Building Structure Design
the Authority that the foundations of the building have been
carried down to a level safe guarding its stability.
11-8. Specifications
Specifications of Material Quality Control and workmanship will
be of high quality and in accordance with the requirements of
ACI Building Codes, Uniform Building Code (UBC) and ASTM Standards.
11-9. Testing of Materials
Regular testing will be carried out of materials such as Aggregates,
Cement, Concrete and Reinforcing Steel and all Architectural materials
the Quality Control and Quality Assurance Criteria laid down in
standards of FIDIC, ASTM, OR ACI/UBC and Project Specifications.
The Quality Assurance Program of the Architect / Engineer may
also be followed.
11-10. Supervision
Construction supervision and quality assurance will be carried
out by full time/top supervision by the designer/supervising engineers/architects/inspectors
etc. as required in these Regulations. Contractor/Builder’s/Developers
full time supervisory staff for the category of buildings in these
Regulations shall carry out supervision and quality control.
|