9-1. Space for Electrical Sub-Station
A minimum space of 16ft. x 21ft.(5m. x 6.5m) (or as per requirement
of KESC) shall be left for electrical sub-station which is abutting
on road side / street or has a clear passage of 16ft.(4.87m).
width, for public sale, commercial, residential building and industrial
building having an area in excess of 25,000Sq.ft.(2323Sq.m) all
Category “III” and Category “IV” buildings.
In the event that KESC sub-station is not required, this space
may be utilized as per Regulations.
9-2. Method of Measuring Minimum Clear Space
The minimum clear space prescribed between a building and from
the property line shall be measured from the external face of
the perimeter wall enclosing the covered or usable area of the
building, at its greatest projection from the building, at right
angles to the plot boundary, and excluding permissible chajjas
and balconies. If there are more boundaries than one in the plot
affecting the building, the above requirements will be satisfied
at all such boundaries also.
9-3. Separate Approach for every Building
Every building more than 35 feet (10.5m) high not abutting on
a street shall have an access for an approach from the street,
open to the sky, at least 13ft.(4m) width.
9-4. Projections beyond Property Limits
No projections or overhanging features shall be permitted beyond
property limits except where permitted under the Regulations.
9-5. Allowable Projections
9-5.1. Maximum allowable projection of chajjas and sunshades
in compulsory open spaces shall be 2.5ft.(0.75m) or half the width
of COS whichever is less.
9-5.2. No construction shall be allowed in the chamfered portion
upto 17ft (5.17m) measured from the adjacent road.
9-5.3. Open balconies projecting on to public streets from buildings
abutting such streets be permitted by the authority such projection
shall not be used as a room as per conditions stated here under:
THE SINDH GOVT. GAZETTE APRIL 04, 2002 469
9-Space Requirements in and About Buildings
Min.height above
street level from
centre of street
Width of Max.length Max. Balconies and
Street of Balconies Projection sunshades.
30ft.(9.13m) & less 23ft.(7m) 2ft.(60cm) 17ft.(5.17m)
than 40ft.(12.18m)
40ft.(12.18m) & less 23ft.(7m) 3ft.(90cm) 17ft.( 5.17m)
than 50ft.(15.2m)
50ft.(15.2m) & above 23ft.(7m) 4ft.(120cm) 17ft.( 5.17m)
In case of corner plots no balcony will be allowed at the corner
of the plot below 17ft(5.17m).
9-6. Residential Buildings
9-6.1. No habitable room shall have a floor area of less than
100Sq.ft.(9.3Sq.m).
9-6.2. The minimum width of a habitable room shall be 8ft.(2.44m).
9-6.3. The minimum floor area of kitchen shall be 50Sq.ft.(4.53Sq.m).
The minimum width of kitchen shall be 6ft.(1.8m).
9-6.4. The minimum areas and widths of W.C.’s and bathrooms
shall be:
Min. Area Min. Width
W.C. 15sq.ft.(1.4Sq.m) 3.5ft.(1.07m)
Shower 15Sq.ft.(1.4Sq.m) 3.5ft.(1.7m)
Combined W.C. and 35Sq.ft.(3.25Sq.m) 4.5ft.(1.38m)
Bathroom
9-6.5. The minimum clear height of rooms under any structure
member shall be except in the cases when central air conditioning
provides are applicable as purchase No.10-8-1:
THE SINDH GOVT. GAZETTE APRIL 04, 2002 470
9-Space Requirements in and About Buildings
Habitable rooms 9.5 ft.(2.65m)
Kitchens 9.5 ft(2.65m)
Bathrooms, W.C.’s, Latrine 8 ft.(2.43m)
Garages and Car porch 7.5 ft.(2.28m)
Passages, galleries, corridors 7.5 ft.(2.28m)
Dress room 7ft.(2.13m)
9-7. Commercial Buildings
9-7.1. The minimum floor area of a shop shall be 100Sq.ft.(9.29Sq.m)
and the minimum width of the shop shall be 8ft.(2.4m).
9-7.2. The shop having a loft shall have carpet area 100sq.ft.
(9.29Sq.m) and a minimum height of 16ft.(4.87m) and with loft
area of not exceeding 40% of the carpet floor area.
9-7.3. The minimum ceiling height of an arcade shall be 8ft.(2.5m).
9-7.4. 40% of the shopping area may have shops of minimum floor
area of 56 Sq.ft.(5.2 Sq.m) provided they are not facing the road.
9-7.5. The minimum clear height of shop will be 10ft.(3m).
9-7.6. Clear width of Arcade between inner surface of the outer
column and shop shall be minimum of 5’-6” and width
from outer column and shop shall be 8’-0”.
Staircases
9-8.1. The riser of all buildings shall not be more than 6 inches
(15 cm) and the tread shall not be less than 10 inches (25 cm)
except for residential houses where the maximum riser shall be
7 inches (18 cm) and the minimum tread will be 9 inches (23 cm).
However, for staircases to lofts, circular staircases to non-public
access mezzanines and heights not exceeding 7 feet 6 inches (2.25
m) staircase risers and treads will be worked out through the
following formula: 2 R + T = 22 where R is riser and T is tread
and the minimum T is 6 inches.
THE SINDH GOVT. GAZETTE APRIL 04, 2002 471
9-Space Requirements in and About Buildings
9-8.2. For all buildings other than Category “I”
buildings and bungalows, the minimum width of staircases shall
be 4ft.(1.2m). The distance from any point to the nearest staircase
shall not exceed 100ft.(30m). The minimum clear head room under
beams and stair landing shall be 7ft.(2.1m).
9-8.3. Other than bungalows, all staircases shall be provided
with a handrails.
9-8.4. A handrail shall be provided on each side of the staircase
when the staircase is 6ft.(1.8m) wide or more.
9-8.5. For all buildings other than bungalows, there shall not
be more than 15 risers between each landing in a straight flight.
Depth of the landing shall not be less than the width of the flight.
9-8.6. Winders shall be permitted in Category “I”
buildings and bungalows only.
9-9. Lifts
No lift will be of capacity less than 6 person, and lifts shall
conform to the technical provisions of BS5655 with respect to
all safety devices, procedures of examination and annual testing/certification
of lifts by a professional engineer of concerned disciplines.
The following recommendations will be considered in the design
of lifts:-
Minimum provision of Lifts.
|
Minimum
Climbing Height |
Minimum Number of Lifts |
Capacity |
|
From 46ft.(14m) to
below 59ft.(18m). |
1 |
450
kg(6 passenger) |
|
59ft.(18m) and above. |
2 |
450
kg(6 passenger) |
Additional number of lifts to be provided by the designer professional
keeping in view the size, speed and size of brand of lift, type
and height of buildings etc.
THE SINDH GOVT. GAZETTE APRIL 04, 2002 472
9-Space Requirements in and About Buildings
9-10. Minimum Requirements of Places of Assembly
The minimum clear heights of places of assembly shall be 12ft.(3.65m).
9-11. Godowns and Warehouses
9-11.1. No godown except a store shall be provided in a residential
building.
9-11.2. Godowns/ware houses shall be designed, adopted or used
for storage purposes only;
9-11.3. In every warehouse and godown there shall be exhibited
by the owner, at some appropriate place, permanently and conspicuously,
a notice incised or embossed on metal, plastic or similar permanent
material in the following form, stating the load for which the
floor has been designed with letters to be at least 1 inch(25mm)
wide & 3 inch(75mm) high. In case of inflammable or explosive
materials, being stored, prior permission from the relevant authorities
shall be obtained.
N O T I C E
This floor has been designed to sustain a superimposed load
of 10 lbs per Sq.ft.(48.9
Kg. Per sq.m) |
|